Product Name | Liquidum Oxygen Plant | |||
Exemplar No. | NZDON- 50/60/80/100 CUSTOMIZED | |||
Brand | NUZHUO | |||
Accessories | Aeris compressor & Re- refrigerandi ratio & Expander | |||
Consuetudinem | Alta puritas Oxygen & Nitrogen & Argon productio machina |
Model | NZDON-50/50 | NZDON-80/160 | NZDON-180/300 | NZDON-260/500 | NZDON-350/700 | NZDON-550/1000 | NZDON-750/1500 | NZDONAr-1200/2000/30y | |
O2 0utput (Nm3/h) | 50 | 80 | 180 | 260 | 350 | 550 | 750 | 1200 | |
O2 Puritas (%O2) | ≥99.6 | ≥99.6 | ≥99.6 | ≥99.6 | ≥99.6 | ≥99.6 | ≥99.6 | ≥99.6 | |
N2 0utput (Nm3/h) | 50 | 160 | 300 | 500 | 700 | 1000 | 1500 | 2000 | |
N2 Munditia (PPm O2) | 9.5 | ≤10 | ≤10 | ≤10 | ≤10 | ≤10 | ≤10 | ≤10 | |
Liquid Argon Ouput (Nm3/h) | -- | -- | -- | -- | -- | -- | -- | 30 | |
Liquid Argon Purity ( Ppm O2 + PPm N2) | -- | -- | -- | -- | -- | -- | -- | ≤1.5ppmO2 + 4 pp mN2 | |
Liquid Argon Pressure ( MPa.A) | -- | -- | -- | -- | -- | -- | -- | 0.2 | |
Consummatio (Kwh/Nm3 O2) | ≤1.3 | ≤0.85 | ≤0.68 | ≤0.68 | ≤0.65 | ≤0.65 | ≤0.63 | ≤0.55 | |
Area occupati (m3) | 145 | 150 | 160 | 180 | 250 | 420 | 450 | 800 |
1. Designe principium huius plantae ex diversa parte fervens cuiusque gasi in aere fundatur.Aer comprimitur, praecoquetur et ab H2O et CO2 remotione ducitur, deinde in commutante calore principali refrigerandus est donec liquatur.Post rectificationem, productio oxygeni et nitrogen colligi possunt.
2. Haec planta est purificatio aeris MS cum processu propagatoris turbinibus boosting.Planta communis est separatio aeris, quae integram supellectilem impletionem et rectificationem ad argonis fabricationem adoptat.
3. Rudis aer accedit ad aerem colum propter remotionem pulveris et immunditiam mechanicam et intrat compressor aeris turbinem ubi aer comprimitur ad 0.59MPaA.Inde in aerem decoctionis ratio accedit, ubi aer refrigeratus est 17 ℃.Deinde fluit ad 2 piscinam hypotheticam adsorbendam, quae vicissim currit, tollenda ab H2O, CO2 et C2H2.
* 1. Postquam purgatus aer permiscet eiecto aere expanso.Deinde comprimatur per medias angustias compressor ad rivos dividendos.Una pars accedit ad commutatorem principalem caloris ad -260K refrigerandum, et ex media parte praecipui caloris commutatoris exsorbetur ad turbinem expansionem ingrediendam.Aer expansus ad praecipuum calorem commutatoris emittiendum redit, postquam in aere compressor boosting fluit.Altera pars aeris ab amplificatore caliditas caliditas boosting, post refrigerationem fluit, ad humiliationem dilatatoris boosting fluit.Deinde ad frigidam cistam refrigerandam accedit ad ~170K.Pars ejus adhuc refrigeratur, et fluit ad imum columnae inferioris per calorem commutatoris.Et alius aerem tentat humiliare betur.propagator.Post ampliatum dividitur in partes II.Una pars ad imam columnae inferioris rectificationis accedit, reliqua redit ad caloris principalis commutatoris, deinde eiectus ad aerem cursus fluit.
2. Post rectificationem primariam in columna inferiore, liquor aer et liquidus purus in columna inferiore colligi possunt.Vastum liquidum NITROGENIUM, liquidum aerem et liquidum purum, fluit nitrogenium ad superne columnam per liquidum aerem et liquidum frigidiorem nitrogenium.Rectum est rursus in columna superiori, posteaquam liquida oxygenii 99,6% puritatis in fundo columnae superioris colligi potest;
et e cista frigida productio liberatur.
3. Pars argonis fractio in superiore columna rudi columnae argonis betur.Sunt 2 partes columnae argonis rudis.Refluxus partis secundae traditur cacumine primae per sentinam liquidam sicut refluxus.Rectum est in rudi columna argonis ad 98.5% Ar.2ppm o2 Argon rudis.Traditur deinde ad medium columnae purae argonis per evaporatorem.Post rectificationem in columna pura argonis, (99.999%Ar) liquidum argon colligi potest in fundo columnae argonis purae.
4. Nitrogenium Vastum de summitate columnae superioris profluit ex arca frigida ad purificatorium, ut aer regenerativus, quies vadit ad turrim refrigerandam.
5. Nitrogenium e vertice adiutoris columnae superioris columnae e archa frigida fluit ut productio per frigidiorem et praecipuum calorem commutatoris.Si NITROGENIUM non opus est, tum aqua turris refrigerationis liberari potest.Ad frigoris capacitatem aquae refrigerationis turris non sufficit, frigida instituenda est.
Q1: Esne mercatura societas vel opificem?
A: Depending on what type of machine you are purchased. Cryogenic ASU, the delivery time is at least 3 months. Cryogenic liquid plant, the delivery time is at least 5 months. Welcome to have a contact with our salesman: 0086-18069835230, Lyan.ji@hznuzhuo.com
Focus ad solutiones mong pu per 5 annos providenda.